| I would recommend you set up email notifications before configuring this. | I would recommend you set up email notifications before configuring this. | ||
| - | Go to the “Services” Page. | + | Click " |
| - | {{:fester:91f9c957b109e4f4bd41d2f8a69e1a6c.png}} | + | {{:fester112:pasted: |
| - | + | ||
| - | Now click on the small spanner icon next to the “S.M.A.R.T.” service (1). | + | |
| A window should now pop up. | A window should now pop up. | ||
| - | In the window leave the “Check interval: | + | In the window leave the “Check interval: |
| - | Fester sets the “Power mode:” drop down selection box to **Never** | + | Fester sets the “Power mode:” drop down selection box to **Never**. This will ensure that the drives are checked no matter what their status. |
| - | Leave the “Difference: | + | Leave the “Difference: |
| - | Now set the drive temperature warning threshold called “Critical: | + | Now set the drive temperature warning threshold called “Critical: |
| - | Now enter in the “Email | + | Now enter in the “Email” text box the internal email address of the user the SMART monitor service is to alert (in Fester’s case this is r**[email protected]**). |
| - | Then click the “OK” button | + | Then click the “Save” button. |
| - | {{:fester:59a1dd0a741f08a38c51fd2abc5f2f42.png}} | + | {{:fester112:pasted: |
| The final thing is to test it works. | The final thing is to test it works. | ||
| Line 29: | Line 27: | ||
| Go back into the SMART service configuration window by clicking on that small spanner icon again. | Go back into the SMART service configuration window by clicking on that small spanner icon again. | ||
| - | In the “Critical: | + | In the “Critical: |
| - | Now click the “OK” button and wait. | + | Now click the “Save” button and wait. |
| Due to the fact that the temperature of the HDDs in the server will be higher than the threshold we have set, a warning email should be triggered. When you get the email you know the service is working. | Due to the fact that the temperature of the HDDs in the server will be higher than the threshold we have set, a warning email should be triggered. When you get the email you know the service is working. | ||
| - | Be sure to return the value in the “Critical: | + | Be sure to return the value in the “Critical: |